Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Arch. cardiol. Méx ; 93(2): 172-182, Apr.-Jun. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1447248

RESUMO

Abstract Aim: To analyse the potential usefulness and clinical relevance of the assessment by echocardiography with left atrial strain, based on the myocardial atrial deformation curves with speckle-tracking velocity vector imaging (VVI), in the analysis of short-form recurrent atrial extra systoles in ambulatory patients not suffering from organic cardiopathy. Methods: We designed a descriptive, prospective, and observational study including 270 patients between the ages of 18 and 75 assessed during an outpatient cardiology consultation attended due to palpitations over a period of two years. Using ambulatory electrocardiographic monitoring, we selected cases with short forms of repetitive atrial extrasystole, isolated or recurrentatrial fibrillation and a control group formed by those patients without repetitive ectopia. All patients underwent a thorough echocardiographic study during their first cardiological visit. Results: The analysis of the dynamic curves segmental deformation generated after an atrial extrasystole can reveal different points of origin of the extrasystole and detect specific anatomical alterations in the interatrial conduction at the level of the Bachmann's fascicle showing different models of electro anatomical activation possibly involved in the appearance of repetitive forms. Higher values of dyssynchrony between the septal and lateral wall and elongation in the time of interatrial electromechanical conduction could also be related to the existence of repetitive ectopic beats. Conclusions: Our ambulatory study employing the left atrial longitudinal strain, particularly in its segmental analysis, provides new insights into its the usefulness and potential clinical relevance.


Resumen Objetivo: Analizar la utilidad y relevancia clínica de la evaluación mediante ecocardiografía basada en las curvas de deformación auricular miocárdica con imágenes vectoriales de velocidad (VVI) de speckle-tracking, en el análisis de las extrasístoles auriculares recurrentes de corta duración en pacientes ambulatorios sin cardiopatía orgánica. Métodos: Se diseñó un estudio descriptivo, prospectivo y observacional que incluyó a 270 pacientes de entre 18 y 75 años evaluados durante una consulta externa de cardiología a la que acudieron por palpitaciones durante un periodo de dos años. Mediante el uso de monitorización electrocardiográfica ambulatoria, se seleccionaron casos con formas cortas de extrasistolia auricular repetitiva, fibrilación auricular aislada o repetitiva y un grupo control formado por aquellos pacientes sin ectopia repetitiva. Todos los pacientes se sometieron a un estudio ecocardiográfico exhaustivo durante su primera visita cardiológica. Resultados: El análisis de las curvas dinámicas de deformación segmentaria generadas tras un extrasístole auricular diferentes modelos de activación electroanatómica posiblemente implicados en la aparición de formas repetitivas. Valores mayores de disincronía entre la pared septal y lateral y el alargamiento en el tiempo de conducción electromecánica intraauricular pudieran también relacionarse con la existencia de latidos ectópicos repetitivos. Conclusiones: Nuestro estudio ambulatorio empleando la deformación longitudinal auricular izquierda, particularmente en su análisis segmentario, proporciona nuevas perspectivas sobre su utilidad y potencial relevancia clínica.

2.
Rev. cuba. invest. bioméd ; 29(2): 203-212, abr.-jun. 2010.
Artigo em Espanhol | LILACS | ID: lil-584734

RESUMO

Las imágenes ecocardiográficas de Doppler tisular y sus derivados (deformación y velocidad de deformación regional), han permitido visualizar el comportamiento de las fibras miocárdicas cuantificando la función cardiaca segmentaria y global. Objetivo: determinar valores de deformación y velocidad de deformación de la fibra miocárdica con alta sensibilidad y especificidad en el diagnóstico de lesiones coronarias significativas en pacientes con angina estable. Métodos: Se realizó un estudio prospectivo de casos y controles a 30 pacientes programados para Coronariografía Invasiva (patrón oro) en el Instituto de Cardiología y Cirugía Cardiovascular (ICCCV) entre el 10 de enero de 2007 y el 1º de junio de 2008. Resultados: los puntos de corte por segmentos mostraron alta sensibilidad y especificidad en la detección de lesiones coronarias para los parámetros de deformación y velocidad de deformación sistólica en los segmentos basales (septal, lateral y anterior) con valores de sensibilidad de 80 por ciento, 87 por ciento y 93 por ciento y especificidad 80 por ciento, 87 por ciento y 73 por ciento respectivamente


Echocardiographic images of tissue Doppler and its derivatives (deformation and regional deformation velocity) allowed us to visualize the behavior of myocardial fibers quantifying the segmental and global cardiac function. To determine the deformation and deformation velocity values of the myocardial fiber with a high level of specificity and sensitivity in the diagnosis of significant coronary lesions in patients presenting with stable angina. The section points by segments showed a high sensitivity and specificity in detection of coronary lesions for the parameters of deformation and systolic deformation velocity in basal segments (septal, lateral and anterior) with sensitivity values of 80 percent, 87 percent and 93 percent and specificity values of 80, 87 percent and 73 percent, respectively


Assuntos
Angina Estável , Cardiomiopatias/diagnóstico , Diagnóstico por Imagem/métodos , Ecocardiografia/métodos , Doença das Coronárias/diagnóstico , Vasos Coronários , Estudos de Casos e Controles
3.
Rev. cuba. estomatol ; 47(2): 215-223, abr.-jun. 2010.
Artigo em Espanhol | LILACS, CUMED | ID: lil-584499

RESUMO

La propuesta de este estudio fue analizar el efecto de la pigmentación y de la desinfección química sobre la deformación inicial y permanente de dos siliconas (Silved Selant y Brascoved) utilizadas en la confección de prótesis faciales. Las muestras para los analisis de deformación inicial y permanente (20 mm × 12,5 mm) fueron confeccionadas de acuerdo con las instrucciones del fabricante. Para cada silicona (n= 40), diez muestras fueron pigmentadas con polvo de maquillaje, diez con óxido de hierro, diez con polvo de cerámica y diez sin pigmentación. Cinco muestras de cada grupo fueron sometidas a desinfección química, con clorhexidina al 2 por ciento por aspersión. Todas las muestras fueron inmersas en suero fisiológico y almacenado en estufa a 35 º ± 1 ºC. Después de 90 días, las muestras fueron sometidas a los exámenes de deformación inicial y permanente. Para ambas propiedades, los datos fueron analizados por el test de Tukey (a= 0,05). Los resultados mostraron que todos los materiales presentaron deformación inicial y permanente independiente de la desinfección química y pigmentación. Los grupos pigmentados con óxido de hierro fueron los que presentaron menor deformación, inicial y permanente, cuando fueron sometidos a desinfección química, independientemente de la silicona usada(AU)


The purpose of present study was to analyze the effect of pigmentation and chemical disinfection on the initial and the permanent deformation of two silicones (Silved Selant and Brascoved) for facial prosthesis. Initial and permanent deformation tests samples (20 mm × 12.5 mm) were made following the manufacturer's instructions. For each silicone (n= 40), ten samples were used for pigmentation with make up power, ten with iron oxide, ten with ceramics power and tem were tested without pigmentation. Five samples of each group were submitted to chemical disinfection using a 2 percent Chlorhexidine spray. All samples were immersed in physiological saline and stored in an oven at 35 º ± 1 ºC. After 90 days, the samples were submitted to initial and permanent deformation tests using a dial indicator. For both properties, data were analyzed by Tukey's test (a= 0.05). The results showed that all the materials had initial and permanent deformation regardless of pigmentation and chemical disinfection. The groups were used for pigmentation with iron oxide showed less initial and permanent deformation when were submitted to the chemical disinfection regardless the silicone used(AU)


Assuntos
Humanos , Pigmentação/fisiologia , Compostos de Silício/uso terapêutico , Subprodutos da Desinfecção/efeitos adversos , Traumatismos Faciais/reabilitação , Prótese Maxilofacial/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA